29
Protection functions

Characteristic 
Operation accuracy
PHLPTOC


n
PHHPTOC

and
PHIPTOC

n

n
)


n
)
Start time

Minimum Typical Maximum
PHIPTOC:
I
Fault

I
Fault







PHHPTOC and PHLPTOC:
I
Fault
   
Reset time 
Reset ratio 
Retardation time 
Operate time accuracy in definite time mode 
Operate time accuracy in inverse time mode 

Suppression of harmonics
RMS: No suppression

n x f
n

Peak-to-Peak: No suppression

1 Not included in REM615

one phase with nominal frequency injected from random phase angle, results based on statistical distribution of 1000 measurements
3 Includes the delay of the signal output contact
4 Includes the delay of the heavy-duty output contact
1 Not included in this product
2 For further reference, see the Operation characteristics table

Parameter Function  Step
Start value
PHLPTOC 
n

PHHPTOC


n

PHIPTOC 
n

Time multiplier PHIPTOC  
Operate delay time
PHLPTOC and PHHPTOC
 
PHIPTOC  
Operating curve type

PHLPTOC
Definite or inverse time

PHHPTOC

Definite or inverse time

PHIPTOC Definite time

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB REM615 ANSI 5.0 FP1 and is the answer not in the manual?

ABB REM615 ANSI 5.0 FP1 Specifications

General IconGeneral
StandardANSI
Version5.0 FP1
Rated Frequency50/60 Hz
HousingPlastic
TypeFeeder protection relay
Communication ProtocolsModbus, IEC 61850, DNP3
MountingFlush mounting
Operating Temperature Range-40 to +70 °C
Protection FunctionsOvercurrent, Earth fault, Thermal overload
Protection DegreeIP54
Input Voltage24-250 V DC / 48-265 V AC