EasyManuals Logo

ABB REM615 ANSI 5.0 FP1 User Manual

ABB REM615 ANSI 5.0 FP1
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
30 REM615 ANSI 5.0 FP1 MOTOR PROTECTION AND CONTROL

Characteristic 
Operation accuracy
EFLPTOC
Depending on the frequency of the measured current: f
n


n
EFHPTOC
and
EFIPTOC


n

n
)


n
)
Start time

Minimum Typical Maximum
EFIPTOC

:
I
Fault

I
Fault







EFHPTOC and EFLPTOC:
I
Fault
   
Reset time 
Reset ratio 
Retardation time 
Operate time accuracy in definite time mode 
Operate time accuracy in inverse time mode 

Suppression of harmonics 
n

1 Not included in REM615

n
, f
n
= 50 Hz, earth-fault current with nominal frequency injected from random phase angle, results
based on statistical distribution of 1000 measurements
3 Includes the delay of the signal output contact

n
, Start value multiples in range of 1.5...20

Parameter Function  Step
Start value
EFLPTOC 
n

EFHPTOC

n

EFIPTOC


n

Time multiplier EFLPTOC and EFHPTOC  
Operate delay time
EFLPTOC and EFHPTOC
 
EFIPTOC

 
Operating curve type

EFLPTOC
Definite or inverse time

EFHPTOC
Definite or inverse time

EFIPTOC

Definite time
1 Not included in this product
2 For further reference, see the Operation characteristics table

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB REM615 ANSI 5.0 FP1 and is the answer not in the manual?

ABB REM615 ANSI 5.0 FP1 Specifications

General IconGeneral
StandardANSI
Version5.0 FP1
Rated Frequency50/60 Hz
HousingPlastic
TypeFeeder protection relay
Communication ProtocolsModbus, IEC 61850, DNP3
MountingFlush mounting
Operating Temperature Range-40 to +70 °C
Protection FunctionsOvercurrent, Earth fault, Thermal overload
Protection DegreeIP54
Input Voltage24-250 V DC / 48-265 V AC

Related product manuals