Section 2 1MAC254287-MB B
DNP3 data mappings
30 REM615 ANSI
Point List Manual
Table 84: SR-1:Set reset (8 pcs)-instance 1 (SRGAPC1)
BI Yes 463 Class 0 Yes TON -2 Generic Time Delay On 2
Input 5
LD0.TONGAPC2.In5.stVal
BI Yes 464 Class 0 Yes TON -2 Generic Time Delay On 2
Input 6
LD0.TONGAPC2.In6.stVal
BI Yes 465 Class 0 Yes TON -2 Generic Time Delay On 2
Input 7
LD0.TONGAPC2.In7.stVal
BI Yes 466 Class 0 Yes TON -2 Generic Time Delay On 2
Input 8
LD0.TONGAPC2.In8.stVal
BI Yes 467 Class 0 Yes TON -2 Generic Time Delay On 2
Output 1
LD0.TONGAPC2.Q1.stVal
BI Yes 468 Class 0 Yes TON -2 Generic Time Delay On 2
Output 2
LD0.TONGAPC2.Q2.stVal
BI Yes 469 Class 0 Yes TON -2 Generic Time Delay On 2
Output 3
LD0.TONGAPC2.Q3.stVal
BI Yes 470 Class 0 Yes TON -2 Generic Time Delay On 2
Output 4
LD0.TONGAPC2.Q4.stVal
BI Yes 471 Class 0 Yes TON -2 Generic Time Delay On 2
Output 5
LD0.TONGAPC2.Q5.stVal
BI Yes 472 Class 0 Yes TON -2 Generic Time Delay On 2
Output 6
LD0.TONGAPC2.Q6.stVal
BI Yes 473 Class 0 Yes TON -2 Generic Time Delay On 2
Output 7
LD0.TONGAPC2.Q7.stVal
BI Yes 474 Class 0 Yes TON -2 Generic Time Delay On 2
Output 8
LD0.TONGAPC2.Q8.stVal
DNP
Object
Type
No
Event
Point
Index
DNP Class Enabled Description
Scale
Factor
IEC61850 Data Attribute Name
DNP
Object
Type
No
Event
Point
Index
DNP Class Enabled Description
Scale
Factor
IEC61850 Data Attribute Name
BI Yes 407 Class 0 Yes SR-1 Set-Reset Flip Flop Trip
(Operate) - 1
LD0.SRGAPC1.Op.general
BI Yes 408 Class 0 Yes SR-1 Q1 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q1.stVal
BI Yes 409 Class 0 Yes SR-1 Q2 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q2.stVal
BI Yes 410 Class 0 Yes SR-1 Q3 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q3.stVal
BI Yes 411 Class 0 Yes SR-1 Q4 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q4.stVal
BI Yes 412 Class 0 Yes SR-1 Q5 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q5.stVal
BI Yes 413 Class 0 Yes SR-1 Q6 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q6.stVal
BI Yes 414 Class 0 Yes SR-1 Q7 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q7.stVal
BI Yes 415 Class 0 Yes SR-1 Q8 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Q8.stVal
BI Yes 416 Class 0 Yes SR-1 Set 1 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Set1.stVal
BI Yes 417 Class 0 Yes SR-1 Set 2 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Set2.stVal
BI Yes 418 Class 0 Yes SR-1 Set 3 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Set3.stVal
BI Yes 419 Class 0 Yes SR-1 Set 4 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Set4.stVal
BI Yes 420 Class 0 Yes SR-1 Set 5 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Set5.stVal
BI Yes 421 Class 0 Yes SR-1 Set 6 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Set6.stVal
BI Yes 422 Class 0 Yes SR-1 Set 7 Set-Reset Flip Flop - 1 LD0.SRGAPC1.Set7.stVal

Other manuals for ABB REM615