EasyManua.ls Logo

ABB REX640 - Mechanical tests; Environmental tests; Product safety; EMC compliance

ABB REX640
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 30. Mechanical tests
Description Requirement Reference
Vibration tests (sinusoidal) Class 2 IEC 60068-2-6 (test Fc)
IEC 60255-21-1
Shock and bump test Class 2 IEC 60068-2-27 (test Ea shock)
IEC 60068-2-29 (test Eb bump)
IEC 60255-21-2
Seismic test Class 2 IEC 60255-21-3
Table 31. Environmental tests
Description
Type test value Reference
Dry heat test 96 h at +55ºC
16 h at +85ºC
1)
IEC 60068-2-2
Dry cold test 96 h at -25ºC
16 h at -40ºC
IEC 60068-2-1
Damp heat test 6 cycles (12 h + 12 h) at +25°C…+55°C,
humidity >93%
IEC 60068-2-30
Change of temperature test 5 cycles (3 h + 3 h)
at -25°C...+55°C
IEC60068-2-14
Storage test 96 h at -40ºC
96 h at +85ºC
IEC 60068-2-1
IEC 60068-2-2
1)
For relays with an LC communication interface the maximum operating temperature is +70
o
C
Table 32. Product safety
Description Reference
LV directive 2006/95/EC
Standard EN 60255-27 (2014)
EN 60255-1 (2009)
Table 33. EMC compliance
Description Reference
EMC directive 2004/108/EC
Standard EN 60255-26 (2013)
Table 34. RoHS compliance
Description
Complies with RoHS Directive 2011/65/EU
1MRS759144 A
REX640
Product version: 1
36 ABB

Table of Contents