EasyManua.ls Logo

ABB Terra 53 - 4.5 Switch the Charger On;Off

ABB Terra 53
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.5 Switch the charger on/off
In case it is necessary to switch off the charger this can be done by turning off the main switch (A
in Figure 2):
1. Open the front door.
2. Locate the main switch (A).
3. Turn the handle counterclockwise to the horizontal position, marked with “0”.
To switch the charger back on, turn the handle clockwise to the vertical position, marked with “1”.
After about a minute the charger should be showing the normal screen (“Connect your car”).
NOTICE
Operating the main switch is quite arduous. Use both hands if needed and
be careful not to injure yourself.
4.6 Climate control precautions
Condensation inside the cabinet can cause damage to the charger, especially when charging. For
this reason the cabinet has a climate control. The climate control is out of function when the power
is off.
When the charger has been without power for several hours (switched off or external power
outage) it is important to activate the climate control before a car is charged to prevent damage to
the charger. This can be ensured by following the next procedure:
1. Do not charge a car!
2. Open the front door of the cabinet
3. Open the left side door if the charger has AC charging capability (G/T type)
4. Switch off the RCD for AC charging (J) by pushing the switch down.
5. Switch off the RCD for DC charging (B) by pushing the switch down.
6. Verify if the Utility group RCBO (C) is switched on (upper position).
7. Switch on the Main switch (A)
8. Close the door
9. Let the climate control function for at least 4 hours
10. Open the doors
11. Switch on the RCD’s (B, J).
12. Close the door
The Charger is now ready to charge an EV.