Operation Manual / TPL85-B14/-B15/-B16
Disassembly and assembly
8
Removing internal part of compressor
casing
8.6
Page 102
© Copyright 2016 ABB. All rights res
erved.
May 2016 HZTL2491_EN Revision B
Attach two shackles (90195) to the support angle (90025) and fasten a
second set of lifting gear to both shackles (90195).
Slightly raise the compressor casing internal part (76000) along with
the wall insert and diffuser using the lifting device (90190).
Use a second set of lifting gear to carefully move the compressor cas-
ing internal part (76000) into a vertical position.
Set down the casing with the flange (
F
) on an underlay.
WARNING
Make sure that the underlay does not slip.
Allow the compressor casing internal part to rest only on the flange (
F
).
Check underlay and adjust if necessary.
If necessary