Operation Manual / TPS44-F.. - TPS61-F..
4 Operation / 4.3 Expected exchange intervals
© Copyright 2020 . All rights reserved. HZTL2412_EN Rev.G March 2020
Influencing parameters
The specified values are only guide values and not guaranteed. The ac-
tual values can deviate considerably from the guide values due, for ex-
ample, to the following influences:
¡ Fuel quality and preparation
¡ Load profile (thermal load cycles, also starts / stops, emergency
shut-downs)
¡ Gas inlet temperature
¡ Frequency and execution of turbine and compressor cleaning
¡ Turbocharger specification
¡ System-specific operating conditions (operating point, combustion
quality, composition of exhaust gas)
For bearing parts
¡ Lubricating oil quality (oil filtration, condition of lubricating oil, oil
monitoring)
¡ Load profile (rpm / speed, pressure conditions, temperature)
¡ State of rotor unbalance (degree of contamination)