Operation Manual / TPS44-F.. - TPS61-F..
Operation
4
Expected exchange inte
rvals
4.3
Page 49
April 2015 HZTL2412_EN Revision E
Influencing parameters
The specified values are only guide values and not guaranteed. The
actual values can deviate considerably from the guide values due, for
example, to the following influences:
Fuel quality and preparation
Load profile (thermal load cycles, also starts / stops, emergency shut-
downs)
Gas inlet temperature
Frequency and execution of turbine and compressor cleaning
Turbocharger specification
System-specific operating conditions (operating point, combustion
quality, composition of exhaust gas)
For bearing parts
Lubricating oil quality (oil filtration, condition of lubricating oil, oil
monitoring)
Load profile (rpm / speed, pressure conditions, temperature)
State of rotor unbalance (degree of contamination)