Wallbox eMH1 – Taking the Wallbox eMH1 out of operation |
25
English
Taking the Wallbox eMH1 out of operation
In case of severe malfunctions or damage to the device, you must take the Wallbox eMH1 out of opera-
tion. To do so, proceed as follows:
Wallboxes eMH1 with integrated RCCB only:
1 Open the housing cover of the wallbox using
the key supplied and flip it up.
2 Flip the pivot lever of the internal RCCB to
the 0 position.
3 Close and lock the housing cover of the
wallbox.
All Wallboxes eMH1:
4 Open your domestic power distribution box
and disconnect the power supply cable from
the electricity grid.
y Wallboxes without integrated RCCB:
In addition, flip the pivot lever of the
RCCB to the0 position.
y Close the domestic power distribution
box.
The Wallbox eMH1 is no longer connected to the electricity grid and can be removed by a qualified spe-
cialist electrical contractor if required.
Danger
Dangerous electrical currents
Always measure the voltage between the phases and the neutral conductor of the power supply cable
before you start dismantling the wallbox.

Table of Contents

Other manuals for ABL WALLBOX eMH1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABL WALLBOX eMH1 and is the answer not in the manual?

ABL WALLBOX eMH1 Specifications

General IconGeneral
ModeleMH1
ManufacturerABL
Connector TypeType 2
InstallationWall-mounted
Protection ClassIP54
Input Voltage400 V
Voltage230/400 V
CategoryWallbox
Charging Power11 kW
Charging Current16 A
Operating Temperature-25°C to +50°C
CommunicationModbus

Related product manuals