EasyManua.ls Logo

Acer AL1931 - 2.7 POWER SUPPLY; 2.7.2 Input Frequency Range; 2.7.3 Quick specification review; 2.7.4 Power Management

Acer AL1931
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
2.7 POWER SUPPLY
(PK10V000000, LAE LAD6019AB5 BLK)
(PK10V000010, LAE LAD6019AB5 IVO)
(PK100005000, LSE9901B1260 BLK)
(PK100005010, LSE9901B1260 IVO)
2.7.1 Input Voltage Range
The monitor shall operate within specification over the range of 90 to 265 VAC power supply.
2.7.2 Input Frequency Range
Input power frequency range shall be from 47.5 to 63 Hz over the specified input voltage
range.
2.7.3 Quick specification review
Input current 1.2A (max) at 90VAC input and full load ,
0.6A (max) at 264 VAC input and full load.
Inrush current @ cold start
30A(0-peak)@ 110Vac ,50A(0-peak) @ 220Vac
(measured when switched off for at least 10 mins.)
Output
Tolerance Output Current
Output Volt - MIN MAX
Volt Tolerance
+12Vdc
±5%
0A 5A 11.4~12.6Vdc
Total output power: 60 Watt max.
Withstanding voltage : 1.5Kvac or 2.2KVdc for 1 minute.
Leakage current : < 0.25mA/100Vac , <3.5mA/230Vac
Efficiency : 80% min. @115V/230VAC, maximum load.
2.7.4 Power Management
2.7.4.1 Meet VESA DPMS proposal
The monitor must comply with the Microsoft On Now specification, with a minimum of three
power management states, as defined by the VESA DPMS document. The front panel of
the monitor must appropriately display the DPMS state, For example:
DPMS ON : The power LED is Blue
DPMS OFF : The power LED is Amber
2.7.5 Power Consumption
On mode 55 Wmax Green
Off mode 5 Wmax Amber
DC power off 5 Wmax Dark
disconnection 5 Wmax
Dark (DC power off)
Amber (DC power on)
Power saving states are measured with speakers attached but not worked.
The recovery time from stand by /suspend/off mode to on mode is 7 seconds
maximum.

Table of Contents

Other manuals for Acer AL1931

Related product manuals