Acer Acer –LCD-P205H
12
6. SOP of firmware upgrade (
Manufacturer of Scaler is Mstar)
6.1 Operational condition:
Equipment: PC, ISP card, signal cable and power cable.
ESD requirements: antistatic wrists, antistatic gloves (fingers), and connecting cable
Name of ISP program: ISP_Tool_v3.7.5.exe
Manufacture of FW IC
PMC/SST/MX
6.2 Operational steps:
1. Connection: connect PC to PCBA with signal cable, and then keep AC and DC in open state
.
2. Adjust ISP programming
Firstly, double click ISP_Tool_v3.7.5EXEI and open ISP program, then select “Device”, next select manufacturer model of
FW IC, which should be correspondent with that of PCBA FW IC. Double click Figure One.
Secondly
download FW software: first select “READ”, and then load FW software in Rooter (Fig.2).
FW IC
Model
One port of ISP
program card
is connected to
PC print port.