EasyManua.ls Logo

Acer P244W

Acer P244W
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 13 -
3.3.7 EMC
Item Condition Spec OK
N.
A
Remark
Electric
Band 1 < 10 V/m
Band 2 < 1 V/m
TCO03
Magnetic
Band 1 < 200nT
Band 2 < 25nT
FCC part 15J class B
EMI
EN55022 class B
After Mass production
under 1dBuv for constant
measure. Besides DNSF
and VCCI class-
2 are
optional.
3.3.8 Reliability
Item Condition Spec OK
N.
A
Remark
MTBF Prediction Refer to MIL-217F > 60,000 Hours
Excluding
CCFL
CCFL Life time
At 25±2, under 7.0mA
40,000 Hours (min)
See Note-4
Note-4: CCFL lifetime is determined as the time at which brightness of lamp is 50%. The typical
lifetime of CCFL is on the condition at 7.0mA lamp current.
3.3.9 Audio performance
Item Condition Spec OK
N.
A
Remark
Preamp + Power amp
(1)Output power
1 Wrms/CH @ 1KHz
(2)THD (@ 1W)
<1%
(3)S/N ratio
>40dB
Speaker Driver
(1)Nominal impedance
4 ohm
(2)Rated input power
1 W/CH
(3)Frequency response
180~20KHz SPL-10dB
(4)Outpu
t sound pressure
level
84 ± 3 dB (1W 0.5M)
(5)Dimension of box
284x60x27mm
2
Audio Control
(1)Volume range
0 ~100 levels
(2)Mute
On/Off

Other manuals for Acer P244W

Related product manuals