c) Pressing the
OPER
and
OPER and OPER
RTTY
buttons yet again will illuminate the yellow
RTTY buttons yet again will illuminate the yellow RTTY
IP
light. This provides an
approximate reading of combined plate current and grid 2 current. The reading should be no higher
than 500 mA (10 LEDs illuminated) for RTTY or 600 mA (12 LEDs illuminated) for SSB and CW.
d) Pressing the
OPER
and
OPER and OPER
RTTY
buttons a final time will restore the upper bar-graph to its normal
RTTY buttons a final time will restore the upper bar-graph to its normal RTTY
function of indicating peak forward power.
NOTE
The auto-protection system will continue to operate in the service mode.
6. SPECIFICATIONS
6-1. Parameters
a) Frequency Coverage: All amateur bands in the 1.8-29.7MHz frequency range; extensions and/or
changes on request.
b) Power Output: 700 W PEP or 500 W continuous carrier.
c) Intermodulation Distortion: Better than 35 dB below rated output.
d) Hum and noise: Better than 40 dB below rated output.
e) Harmonic Output Suppression: Better than 50 dB below rated output.
f) Input and Output Impedance:
- Nominal value: 50 Ohm unbalanced, UHF (SO-239) type connectors;
- Input circuit: broadband, VSWR less than 1.3:1, 1.8-30 MHz continuously (no tuning, no switching);
- Bypass path: VSWR less than 1.1:1, 1.8-30 MHz continuously, 200 W maximum;
- Output (antenna) impedance matching capability: VSWR up to 3:1 or higher.
g) RF Gain: 11dB typically, frequency response less than 1dB (50 to 70 W drive power for rated
output).
h) Primary Power: 85-132 V/170-264 V ac (100, 110, 120, 200, 210, 220, 230 & 240 V nominal taps),
+10% -15% tol.), 50-60 Hz, single phase, 1200 VA.
i) Complies with CE safety and electromagnetic compatibility requirements as well as FCC-regulations
(10 & 12 m band locks provided).
j) Size & Weight (operating): WxDxH: 406x315x150mm, 16kg (16x12.4x5.9 inches, 35.2Lbs).
k) Operating environments:
- Temperature range: 0 to +50 degrees Celsius;
- Humidity: up to 95% @ +35 degrees Celsius.
- Height: up to 3000 m above sea level without output deterioration.