Blood Monitoring SystemGlucose
User's Manual
2010 ACON Laboratories, Inc.
Number: 1150589401
Effective date: 2010-xx-xx
ACON Laboratories, Inc.
10125 Mesa Rim Road,
San Diego, CA 92121, USA
EC REP
MDSS GmbH
Schiffgraben 41
30175 Hannover, Germany
0197

Questions and Answers

  • K
    kimberly51Aug 14, 2025
    What to do if Acon Blood Glucose Meter shows insufficient sample?
    • M
      Michael LewisAug 14, 2025
      If you get an error due to an insufficient sample with your Acon Blood Glucose Meter, repeat the test, making sure you apply enough sample to completely fill the test strip check window.
  • A
    Amy KleinAug 17, 2025
    What to do if Acon On Call test strip is contaminated?
    • E
      edwardbrownAug 18, 2025
      If the test strip is contaminated or has already been used with your Acon Blood Glucose Meter, repeat the test using a new test strip.
  • P
    Peter ReevesAug 21, 2025
    How to fix Acon Blood Glucose Meter if the battery is damaged?
    • K
      Kathy LewisAug 21, 2025
      If the battery of your Acon Blood Glucose Meter may be damaged or not charged, replace it with a new one.
  • M
    Micheal SmithAug 25, 2025
    What to do if test strip was removed during Acon On Call Blood Glucose Meter test?
    • G
      Gabrielle Rivera MDAug 25, 2025
      If the test strip was accidentally removed during the test with your Acon Blood Glucose Meter, repeat the test, making sure the test strip remains in place throughout the entire process.
  • K
    Kim SchneiderAug 28, 2025
    What to do if sample was applied too soon on Acon On Call?
    • C
      Cole GrimesAug 28, 2025
      If you applied the sample too soon to the test strip with your Acon Blood Glucose Meter, repeat the test and make sure to apply the sample only after the blood drop/test strip icon appears on the meter display.
  • M
    melindajohnsonAug 31, 2025
    What to do if temperature is too high for Acon Blood Glucose Meter?
    • T
      torresshawnAug 31, 2025
      If the temperature has exceeded the operating limits of your Acon Blood Glucose Meter, move to a cooler environment and then repeat the test.
  • L
    Lisa VasquezSep 3, 2025
    What to do if temperature is too low for Acon On Call Blood Glucose Meter?
    • C
      Cindy RowlandSep 3, 2025
      If the temperature is below the operating limits of your Acon Blood Glucose Meter, move to a warmer environment and repeat the test.
  • K
    Kenneth GarciaSep 7, 2025
    How to fix Acon On Call power on self check error?
    • B
      Bryan ShawSep 7, 2025
      If you encounter a Power On self-check error with your Acon Blood Glucose Meter, remove the battery for 30 seconds, then reinsert it and turn the meter on again. If the problem continues, contact your local dealer.
  • L
    Lauren NelsonSep 10, 2025
    What causes internal calibration error in Acon Blood Glucose Meter?
    • M
      michelleriveraSep 10, 2025
      If your Acon Blood Glucose Meter shows an internal calibration check error, and if there's a cell phone, radio frequency source, or a high On/Off electrical source nearby, increase the distance between the meter and these sources, then retest. If the problem persists, contact your local distributor.

Summary

On Call Advanced Blood Glucose Meter

Meter Display Symbols and Usage

Control Solution Usage and Precautions

Installing the Battery

Install the Battery

Step-by-step instructions for installing the meter's batteries.

Meter Setup Before Testing

Coding the Meter

Instructions for inserting the code chip to match test strips for accurate readings.

Adjusting Meter Settings

Setting the meter's clock, date, time, and various configurable features.

Performing a Quality Control Test

Quality Control Test Procedure

Step-by-step guide for performing a quality control test using control solution.

HI and LO Messages

Explanation of "HI" and "LO" messages indicating out-of-range blood glucose levels.

Testing Your Blood

Interpreting Quality Control Results

How to interpret QC results and troubleshoot if they fall outside the control range.

Getting a Drop of Blood

Instructions for obtaining a blood sample from fingertips, forearm, or palm.

Fingertip Testing Procedure

Lancing Device Setup and Operation

Preparing and using the lancing device for fingertip blood sampling.

Forearm or Palm Testing Procedure

Lancet Precautions and Test Execution

Testing Blood Glucose (Step 2)

Applying blood to the test strip and initiating the measurement process.

Interpreting Results and Handling Errors

Understanding Result Messages

Troubleshooting Guide

Meter Error Messages and Solutions

Lists common meter error codes, their causes, and recommended solutions.

Acon On Call Specifications

General IconGeneral
Test Time5 seconds
Blood SampleCapillary whole blood
Result CalibrationPlasma-equivalent
Memory300 tests
Battery LifeApproximately 1000 tests
Operating Humidity10% to 90% relative humidity
Hematocrit Range30% to 55%
Measuring Range1.1 - 33.3 mmol/L (20 - 600 mg/dL)