EasyManua.ls Logo

ACTi E89 - Page 29

ACTi E89
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.acti.com
Hardware Manual
29
To connect input devices (DI), map the pins to one of the pin combinations below:
Device
Pin
Mapping Instructions
Digital Input 1 (DI1)
GND
Connect the wires of the first input device to GND
and DI1.
DI1
Digital Input 2 (DI2)
GND
Connect the wires of the second input device to GND
and DI2.
DI2
To connect output devices (DO), map the pins to one of the pin combinations below:
Device
Pin
Mapping Instructions
Digital Output 1 (DO1)
12V
Connect the wires of the first output device to 12V
and DO1.
DO1
Digital Output 2 (DO2)
12V
Connect the wires of the second output device to 12V
and DO2.
DO2
The table below shows the DI/DO connection specifications:
Device
DI
Connection design
TTL - compatible logic levels
Voltage
To trigger (low)
Logic level 0: 0V ~ 0.4V
Normal (high)
Logic level 1: 3.1V ~ 30V
Current
10mA ~ 100mA
DO
Connection design
Transistor (Open Collector)
Voltage & Current
< 24V DC, < 50mA
Typical Connection
Based on these specifications, if the DI device has a voltage of 0V ~ 30V or the DO device has a
voltage of < 24V (< 50mA), then the camera can supply internal power to these devices and there
is no need to connect the DI/DO device to an external power source.

Related product manuals