ActronConnect Installation & Commissioning Guide - Website
Doc. No.9590-1001 Version No.3.0 150901C
WIRING DIAGRAM
R
This drawing remains the intellectual property of Actron Engineering
Pty Ltd. Reproduction, modification and/or distribution are prohibited
without written consent.
Revision
Description:
Drawing No:
B
WD0907
Rev.
Description
Date
By
PCR
ORIGINAL
A4
Size:
Base
Model No:
Variation:
Variation Code:
A
SRM EVAPORATOR WITH EC FAN MOTOR, 8Z-VAV ULTIMA
MODULE & OPTIONAL ACM WIFI MODULE & POWER SUPPLY
IMPORTANT:
DO NOT MOUNT WIFI MODULE
DIRECTLY ON EVAPORATOR UNIT
- FOR OPTIMUM PERFORMANCE OF
WIFI SIGNAL MOUNT 1 METRE AWAY
& NOT ABOVE EVAPORATOR
- MOUNT MINIMUM 1 METRE BELOW
ROOF
WIFI
MODULE
3G LPW WIFI
ETH
E2
RST
MODE
ETH
AC
PWR
P1
EXV
SCRN
COM
PWR
KEY
COM
DATA
EARTH
NEUT
ACT
INDOOR
COIL OUT
SENSOR
INDOOR
COIL IN
SENSOR
EXV
IF-1
1 EC
EC CONTROL
ECM
CONTROL
MODULE
FIELD WIRING BY
INSTALLER
FIELD WIRING BY INSTALLER -
CABLE MUST BE 2 CORE SHIELDED CABLE WITH SHIELD WIRE
CONNECTED TO THE SCREEN / COMMON TERMINAL
(EITHER 2C 14/0.20 SHIELDED OR 2C TWISTED PAIR 7/0.30 SHIELDED CABLE ACCEPTABLE)
TO OUTDOOR UNIT
INDOOR FAN (IF)
INTERNAL AUTO RESET
OVERLOAD PROTECTION
FERRITE
EMC-1
E
N
A
N
A
POWER
COM
KEY
SENSOR
DO NOT
CONNECT
SCREEN
AT WALL
CONTROL
SCREEN
WIRES
POWER
COM
KEY
SENSOR
ULTIMA MODULE
(8Z-VAV)
AMIB
DATA
ZONE
8
ZONE
7
ZONE
6
ZONE
5
ZONE
4
ZONE
3
ZONE
2
ZONE
1
TO ZONE 2 - 8
240V
MAINS
ZONE
MOTOR
AM-ZC
ZONE
CONTROL 1
AM-ZS
ZONE
SENSOR 1
LOG
ULTIMA 8Z-VAV MODULE CONNECTIONS & ACCESSORIES
(SRM MODELS ONLY)
BROWN
BLUE
BROWN
BLUE
ANTENNA
+V
-V
N
A
AC IN
DC OUT
ADJ
ACM POWER SUPPLY
(240VAC - 12VDC 1.3A)
BROWN
BLUE
GREEN / YELLOW
BRN / WHITE (GREEN)
BROWN
LEGEND
AMIB
ACM
EXV
IF
IFRC
TX
WC
EMC
F
8Z-VAV
05-11-2013MH
Drawn:
Date:
Approved:
MJH
Date:
05-11-2013
IMPORTANT :
DO NOT MOUNT ACM DIRECTLY ON INDOOR UNIT.
- FOR OPTIMUM PERFORMANCE OF Wi-Fi SIGNAL
MOUNT 1 METRE AWAY (OR GREATER) AND
NOT ABOVE THE INDOOR UNIT.
- MOUNT MINIMUM 0.5 METRE BELOW ROOF LINE.