E
ActSafe Ascenders use specially
designed lithium-based batteries
with a very high energy density and
are therefore very compact, light-
weight and extremely powerful.
Due to the high energy the batteries
contain, it is of utmost importance
that they are treated with care and
that the user has read the following
section with attention. This is for
your own safety, but also for optimal
Battery life and performance.
ActSafe recommends users to follow
the Battery care guidelines below for
optimal lifetime and performance:
» Battery can stay connected
to ACX during transport or
short term storage (1 week).
For longer storage, disconnect
the Battery and do a maintenance
charge every 3 months
» Always charge batteries as
soon as possible after use
» Disconnect batteries from
the charger after charging
» Always store batteries
fully charged
» Store batteries between
5°C (41°F) and 25°C (77°F)
E.01 THE ASCENDER BATTERY
DANGER
Not following instructions
may result in DAMAGE
TO PROPERTY, SERIOUS
BODILY INJURY OR DEATH.
Note – Battery lifetime
Under normal service conditions
it is expected that the Battery will
last up to 5 years. The lifetime
is dependent on the intensity of
use, how much load is lifted and
the operational temperatures.
See also section E.09.