34
© Copyright ActSafe Systems AB
TROUBLE SHOOTNG GUIDE
The ascender switches o when newly recharged
The grab on the rope is poor, the rope slips
Ascender operates at very low speed
The lifting capacity is notably weak
PROBABLE CAUSE REMEDY
The charging process is incomplete
due to oxidation on the pins.
Clean the pins according to manual and recharge the battery.
The charger is broken/damaged.
Repair/replace the charger, contact ActSafe
or an approved distributor.
The battery is too cold. Let the ascender heat up by operating with load at low speed.
The battery is at.
The ascender is in need of repair and service,
contact ActSafe or an approved distributor.
PROBABLE CAUSE REMEDY
Rope connected incorrectly. Reconnect the rope.
The rope is not suitable
for the ascender.
Change the rope.
The rope grab is worn.
The ascender is in need of repair and service,
contact ActSafe or an approved distributor.
PROBABLE CAUSE REMEDY
The battery is running low, only a few
percent of the capacity is remaining.
Recharge the battery.
The ascender is over loaded. Lighten the load.
The battery is to cold. Let the battery heat up by operation with load at low speed.
PROBABLE CAUSE REMEDY
The charging process is incomplete
due to oxidation on the pins.
Clean the pins according to manual and recharge the battery.
The battery is damaged.
The ascender is in need of repair and service, contact ActSafe
or an approved distributor.
The battery is too cold. Let the ascender heat up by operating with load at low speed.