EasyManua.ls Logo

ActSafe T1-16 - Page 74

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
User’s Manual T1-16 Tactical Ascender
TROUBLE SHOOTNG GUIDE
The remote control cannot operate the winch when LED is green
The LED on the remote ashes red
The ascender is very hot and there is no response to the speed handle
or it operates at very slow speed
PROBABLE CAUSE REMEDY
The distance to the winch is too far. Move closer to the ascender or replace the battery of the remote.
There are objects disturbing
the signal.
Move closer to the ascender to get a stronger signal.
The ascender is not powered up. Turn the ascender on.
Wrong remote control is used. Change to correct remote control.
PROBABLE CAUSE REMEDY
The battery is running low. Replace the batteries of the remote control.
The remote is corrupt. Consult ActSafe or an approved distributor.
PROBABLE CAUSE REMEDY
The ascender is over heated. Wait for the ascender to cool down.
The Emergency brake is dicult/impossible to operate
PROBABLE CAUSE REMEDY
The ascender is powered up. Turn the ascender o.