26
SYSTEM MENU
DMX State:
The DMX state mode serves as a precautionary measure in case the DMX signal is lost. It determines
the running mode the xture will enter when the DMX signal is lost. It can also be set as the default
operating mode when power is applied.
1. Plug in the xture and press the MODE button until “d.XXX” is displayed. “XXX” represents the
current displayed DMX address.
2. Press the SETUP button until “nodn” is displayed. Use the UP and DOWN buttons to scroll through
the DMX states.
• - “bLAC” (Blackout): If the DMX signal is lost or interrupted, the unit will go into standby mode.
• - “LASt” (Last State): If the DMX signal is lost or interrupted, the xture will maintain its last DMX
setup. If power is applied and this mode is set, the unit will automatically enter the last DMX setup.
• - “ProG” (Auto Run): If the DMX signal is lost or interrupted, the unit will automatically enter Auto
Run mode.
3. Once you nd your desired setting, press SETUP to exit.
WiFly On/Off and Wireless Addressing:
This function activates the WiFly control and allows you to set the WiFly address. Note that the address
must match the address set on the WiFly TransCeiver or WiFly controller.
1. Plug in the xture and press the MODE button until “rCXX” is displayed. This indicates the wireless
setup mode.
2. Use the UP or DOWN buttons to turn the Wireless function “On” or “Off”.
3. Press the SETUP button to enter the Wireless address menu. Use the UP or DOWN buttons to
select your desired Wireless address.
Activate IR Sensor:
This function activates or deactivates the IR sensor, which allows you to control the xture using the
UC IR remote.
1. Plug in the xture and press the MODE button until “dXX” is displayed. “XX” represents either “on”
or “oF” (Off).
2. Press the SETUP button until “IrXX” is displayed. “XX” represents either “on” or “oF” (Off).
3. Use the UP or DOWN buttons to either activate the remote function (On) or deactivate it (Off)
Secondary Setting:
The Secondary setting designates the unit as a “Secondary” unit in a Primary-Secondary setup.
1. Plug in the xture and press the MODE button until “SEcd” is displayed. The unit is now designated
as a “Secondary” unit in a Primary-Secondary setup
Default Running Mode:
The Default Running mode restores all modes to their default settings when activated.
1. Plug in the xture and press the MODE button until “dXX” is displayed. “XX” represents either “on”
or “oF”.
2. Press the SETUP button until “dEFA” is displayed.
3. Simultaneously press the UP and DOWN buttons. Press the MODE button to exit.