System Programming (contd)
Table 1: Access Capability
Access
Capability
Time Condition of
BA Group(s)
Access
Action
CMC
Signal
Log and
Print
Programming
Required
On Open and
Access
Opening Opening Person can open
and access any
time.
Inside or
Outside
Schedule
Off Access No Signal Access (1)
Access irr & open
plus
can open
irregular
On Open and
Access
Opening Opening Inside
Schedule
Off Access No Signal Access (1)
On Open and
Access
Irregular
Opening
(PVF)
Irregular
Opening
Same as above,
but an irregular
event will be
flagged for
access outside
of schedule
(PVF).
Outside
Schedule
Off Access No Signal Irregular
Access
Access irr & open
Plus
can not open
irregular
On Open and
Access
Opening Open and
Access
Inside
Schedule
Off Access No Signal Access (1)
On No Access No Signal No Access
Person can open
and access, but
only within
schedule.
Outside
Schedule
(2)
Off No Access No Signal No Access
Can access &
open
plus
can not
open irregular
On No Access No Signal No Access Inside
Schedule
Off Access No Signal Access (1)
On No Access No Signal No Access
Person cannot
open, but can
access within
schedule.
Outside
Schedule
(2)
Off No Access No Signal No Access
Can access
plus
can not
open
irregular
On No Access No Signal No Access Person cannot
gain access at
any time.
Inside or
Outside
Schedule
Off No Access No Signal No Access
Can not access
Notes: 1. Nothing will be logged or printed if the Log Option = N. Selectable for each reader.
2. Access can be granted by establishing a temporary schedule.

Table of Contents

Other manuals for ADT Focus 200 Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Focus 200 Plus and is the answer not in the manual?

ADT Focus 200 Plus Specifications

General IconGeneral
BrandADT
ModelFocus 200 Plus
CategorySecurity System
LanguageEnglish

Related product manuals