Adtech CNC Technology Co., Ltd. 11. System parameters
- 55 -
038 JOG Speed(mm/min)
041 Wheel Coefficient
Range : 1~9999
Unit : mm/min
Authority : Operation admin or higher
Default : 1000, 9000
Effective time : Instant
Note : Set manual speed and handwheel speed;
The start speed and acceleration in this mode are determined by 013,
014, 015, 016, 017, 018, 019, 020;
042 M Code Delaytime(ms)
Range : 1~9999
Unit : ms
Authority : Operation admin or higher
Default : 100
Effective time : Instant
Note : Set the waiting time (unit: ms) after executing M code
043 X HOME Offset(pulse)
044 Y HOME Offset(pulse)
045 Z HOME Offset(pulse)
046 4 HOME Offset(pulse)
Range : -9999~9999
Unit : Pulse
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : Set the compensation home offset (unit: pulse) after axis home operation.
First, complete the mechanical home operation, offset corresponding
pulse, and then set this point as mechanical home.
Note: This parameter is invalid during program home operation.
047 Line number
Range : 0~64
Unit : None
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : While editing G code manually, add a line number Nxxxxx automatically
in a new line;
0 indicates that this function is disabled;
048 System Baudrate
Range : 9600~115200
Unit : None
Authority : Operation admin or higher
Default : 115200
Effective time : Restart
Note : The communication rate setting when DNC or other PC software and this
controller are in RS232 communication mode