EasyManuals Logo

Adtech ADTECH9 Series Programming Manual

Adtech ADTECH9 Series
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
ADTECH9 Series CNC Programming Manual
Example: Six-axis motion MOVEASC[0,6,1,100,2,100,3,100,4,100,5,100,6,100]
Returned value: If correct, it returns 0; If error, it returns the value >1
4.10.14. WRITEOUT Write Physical Output
Function description: Write physical output (OUT)
Parameter NUM Port No. VALUE output level (0 or 1)
Returned value: If correct, it returns 0; If error, it returns the value >1
INT16U WRITEOUT(INT32U NUM,INT8U VALUE)
4.10.15. WRITELED Write Physical LED
Function description: Write physical LED
Parameter NUM: Port No. VALUE output level (0 or 1)
Returned value: If correct, it returns 0; If error, it returns the value >1
INT16U WRITELED(INT32U NUM,INT8U VALUE)
4.10.16. READOUT Read Physical Output
Function description: Read the status of physical output (OUT)
Parameter NUM: Port No.
Returned value: If correct, it returns 0 for low electrical level or 1 for high electrical level;If error, it returns the
value>1
INT16U READOUT(INT32U NUM)
4.10.17. READIN Read Physical Input
Function description: Read the status of Physical Input (IN)
Parameter NUM: Port No.
Returned value: If correct, it returns 0 for low electrical level or 1 for high electrical level;If error, it returns the
value>1
INT16U READIN(INT32U NUM)
4.10.18. READLED Read Physical LED
Function description: Read the output status of the physical LED
Parameter NUM: Port No.

Table of Contents

Other manuals for Adtech ADTECH9 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech ADTECH9 Series and is the answer not in the manual?

Adtech ADTECH9 Series Specifications

General IconGeneral
BrandAdtech
ModelADTECH9 Series
CategoryControl Systems
LanguageEnglish

Related product manuals