ADTECH9 Series CNC Maintenance Manual
- 121 -
Effective time : Restart
Note : Used to configure Ethernet parameters, which shall comply with the
actual network settings, or else it can’t be accessed normally.
After configured successfully, the user can perform the ping command
test on the PC of same network segment (same subnet mask) in the
intranet. The connection has error if the return overtimes. Please check
the physical connection.
The network environment requires independent NC network. Do not
connect to office network or Internet, because the broadcast in the
network and regular query of windows will block the network
communication of NC.
040 This parameter is invalid (Standby)
041 Feed speed setting En
Range : 0~1
Unit :
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : This parameter is used to modify the interpolation speed in
programming, making F programming invalid.
Used for the cases that processing codes requires ignoring F-value.
042 G00 Inp mode Enable
Range : 0~1
Unit :
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : Used to set whether G00 instruction is moved with G01 mode
If G01 mode is used, the interpolation speed shall follow the setting of
minimum speed;
The acceleration is the interpolation acceleration.