ADTECH9 Series CNC Maintenance Manual
- 122 -
043 Abnormal memory position jump enable
Range : 0~2 (corresponding OFF position memory, and status memory)
Unit : None
Authority : Operation admin or higher
Default : 0(OFF)
Effective time : Instant
Note : OFF: turn off this function
ON: turn on this function; when turned on, the processing ends because
the processing code has abnormal condition during processing; the
processing can be continued from the break point.
044
Pause Z to safe altitude
045 Pause A to safe altitude
Range : OFF workpiece coordinates, machine tool coordinates
Unit :
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : OFF: turn off this function
ON: turn on this function; when turned on, press the [Pause] key during
code processing or execute home operation in home mode, Z axis or A
axis lifts to the safe altitude set by P1.049 or P1.050 automatically
(workpiece coordinates or machine tool coordinates).
046
Program home reference point enable
047 Mechanical home reference point enable
Range : 0~1
Unit :
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : OFF: turn off this function