ICAM-520/500 User Manual 32
4.5.8.1 Digital Input and trigger input
There are two digital inputs (Pin 8, 9) that support debouncer features. The
debouncer feature identifies the valid and invalid input signals via setting the
debouncer value (the minimum period of time for the valid signal). In this way, the cir-
cuit will only respond to the signal that the pulse width is greater than the debouncer
value.
Trigger in: default setting debouncer 50 us.
4.5.8.2 Digital output
There are two digital outputs (Pin 10,11), each digital output supports inverter and
can be configured as two different modes, including direct output.
Direct output:
The digital output signal is active when a valid command occurs, and the delay time
can be set as well.
ByPass Mode:
The digital output signal is active when a valid digital input occurs.