Table 3
Cap installation:
Hook the device cap at the top and pivot it down onto the back panel, then make it audibly click into place.
Checkthermseatofthedevicecaponthebackpanel.
5. Specification and application areas for contractors
5.1 Specification
(The details on the type plate apply)
5.2 Application areas
Specicelectricalresistanceandspecicelectricalconductivity
Ageneraltestcerticate[Germany]asvericationofsuitabilityregarding
noise emissions has been issued for the instantaneous water heater series
DDLELCDbasedontheStateBuildingRegulations[Germany].
DIN 4109
PA-IX xxxx/I
AEG
Table 4
For contractors
Type DDLE LCD 18 DDLE LCD 18/21/24
with selectable output
DDLE LCD 27
Rated output kW
18 18 21 24 27
Rated current A 26.0 28.5 30.3 34.6 39
Fuses A 25 32 32 35 40
Selectable output no yes yes yes no
Pressure drop *
with DMB
without DMB
MPa (bar) / l/min
MPa (bar) / l/min
0.08 (0.8) / 5.2
0.06 (0.6) / 5.2
0.08 (0.8) / 5.2
0.06 (0.6) / 5.2
0.1 (1.0) / 6.0
0.08 (0.8) / 6.0
0.13 (1.3) / 6.9
0.10 (1.0) / 6.9
0.16 (1.6) / 7.7
0.12 (1.2) / 7.7
Throughput limit (DMB) l/min
Colour
8.0
white
8.0
white
8.0
white
9.0
orange
9.0
orange
Nominal capacity 0.4 l
Type sealed/unvented
Rated operating pressure 1 MPa (10 bar)
Weight 3.6 kg
Protection class to EN 60335 1
Protection level to EN 60529 IP 25
Test symbols see type plate
Building Regulation test
certificate [Germany]
PA-IX xxxx/I applied for
Water connection G ½” (male thread)
Power supply 3/PE ~ 400 V - 50/60 Hz
Bare wire heating system 900 Ωcm (see Table 4)
Cold water inlet temperature max. 60 °C
Applications water with low limescale levels and those with limescale content
Throughput “ON” ≥ 2.5 l/min
Details as application ranges for different reference temperatures
standard details
at 15 °C
at 20 °C at 25 °C
Resistance
Conductivity
Conductivity
Ωcm
mS/m
µS/cm
≥ 900
≤ 111
≤ 1110
≥ 800
≤ 125
≤ 1250
≥ 735
≤ 136
≤ 1360