VISITOR CODES (FOR OUTPUT 1 ONLY) (Location 40)
The Visitor Codes are temporary user codes for Output 1 (mainly for door strike in access control).
They can be programmed as “One Time Codes” or “Codes with Time Limit”. The Visitor Codes
will be cleared automatically after use if they are one time codes, or, when the allowed time
expires.
(1) LOCATION
Key in Location
(2) VISITOR ID
--- 50 Visitor IDs for the 50 visitor codes. They are Two-digit numbers
=
(3) VALID PERIOD
The codes in this box MUST be two digits and they represent the time of operation.
--- One Time Code
One Time Code has no time limit but it can only be used for ONCE. It is cleared by the
system automatically after use.
- --- Time Limit in Hour(s)
(4) VISITOR CODES
NOTE: All Visitor Codes will be cleared after power down to prevent extension/confusion of
their valid time limit.
(5) VALIDATION
Press key once. Two-beeps confirms the entry.
SYSTEM REAL-TIME-CLOCK (Location 55)
This 24 hour real-time-clock provides the daily time base for starting and stopping the function of
inhibition to relay output 1 (mainly for electric door lock strike).
No real-time-clock setting is required if daily start-stop inhibition at Location 56 is not
enabled.
(1) LOCATION
Key in Location
(2) CURRENT REAL TIME
– The current time in Hour and Minute. The allowed time figure is 00:00 – 23:59
The time setting is based on 24 hours daily with the first two digits for hours and
the last two digits for minutes. The time in second always starts at 0 0.
(3) VALIDATION
Press key once.
Two-beep confirms the setting and the clock starts to count in 24 hour basis from the programmed
current time.
Programming Examples:
a) Set the current time of “10:30” (AM) to the keypad ----
b) Set the current time of “6:45” (PM) to the keypad ------
IMPORTANT NOTE:
1) The real-time-clock stops after power failure, which makes the real-time inhibition loses
its time base. It is necessary to re-program the system’s real-time-clock unless the
keypad is back up with UPS.
2) The keypad gives warning beeps of 3 fast beeps / 5 seconds continuously after
power failure until the real-time-clock is re-programmed.
3) No “after power failure warning beep” will be given if Location 56 is not programmed
with Start/Stop times.
4) Suggest to program the clock every 3-6 months to keep time accuracy; or when time
deviation is found.
CURRENT REAL TIME VALIDATIONLOCATION
(3)
HOURS MINUTES
(2)
(1)
The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with
a two-digit number of 01 to 99. The visitor code is cleared by the system when
the time limit reaches.
4-8 DIGITS
-
or
-
VISITOR CODE VALIDATIONLOCATION VISITOR ID VALID PERIOD
(5)(4)(3)(2)(1)
-
Clear all the Visitor Codes in Location 40. Please see the Programming example
below for the details.
The Visitor Codes can be 4-8 digits for Manual Mode code entry.
The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code
entry.
The Visitor Codes can not reset Duress Output.
When a new Visitor Code is put in the same Code box, the old code is replaced.