This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1
Setting
Description
0
Do not send Report
1
Send Report
Parameter 16: Minimum Temperature change to report
This value defines the minimum change of temperature to cause an unsolicited report of temperature to the
central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However,
periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 20
Setting
Description
0
Disabled
1 - 100
1/10 degree
Parameter 17: Minimum humidity change to report
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central
controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However,
periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 5
Setting
Description
0
Disabled
1 - 20
%
Parameter 18: Periodic Reports
This parameter defines the time interval to send an unsolicited report.
If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on
temperature/humidity changes, managed by configuration parameters 16 and 17, may still be active.
Size: 2 Byte, Default Value: 43200
Setting
Description
0
Disabled
900 - 65535
Seconds
Parameter 255: Reset Parameter
This parameter helps reset configuration parameters and the device to factory defaults
Size: 4 Byte, Default Value: 0
Setting
Description
1 - 1431655764
(0x55555554)
Reset all Parameter settings to their default settings.
1431655765
Completely factory reset sensor and send device reset locally
notification.