How to Achieve & Maintain IP55 Rating
The IP55 rating attached to this unit is only achieved if the below steps have been
followed. This is to prevent any unwanted water and/or bug ingress that can cause
various issues with functionality and will void the warranty if not followed.
Step 1 Mount to location
Step 2 Seal unit
Step 3 Close unit
Ensure the security screws or
cam lock is adequately closed to
ensure a correct seal.
Seal all mounting or cable holes by using sealant
such as silicone.
Ensure that any products being used are safe to use as some
products can cause damage to the unit and/or the mounting
location.
If surface mounting, seal around the back box
especially when used on an uneven surface.
Use the provided mounting holes to attach
the intercom via chosen mounting option.