The altitude of installation site should be below 2000m,more than 2000m above the sea level will cause
derating.
The ambient temperature of installation site should be between -25 °C and +60 °C (between -13 °F and
140 °F).
Install the inverter directly exposing to strong sunshine is not recommended, the excess heating might
lead to power reduction.
Leave enough effective space around the inverter for better ventilation.
Vertical installation, wiring area must be downside, lateral installation is not allowed; in backward tilted
installation, tilt angle should not exceed 30 degrees; Forward tilted, horizontal or inverted installation is
not allowed.