10. Location
It is recommended that any soft material ooring is removed
from where the AGA Module will be installed.
Any adjacent walls that project above the height of the hob
must be of heat resistant material.
The side wall above the hob shall be greater than 60 mm from
the appliance.
Surfaces over the top of the appliance MUST NOT be closer
than 650 mm.
The vent slots in the back of the top plate (or shroud) must
not be obstructed.
If possible, any hot water pipes should be directed away from
the appliance. In the event it is not possible the extension
channel section at the rear of each side plate may be
removed. If required to clear hot water or ue pipes with the
following provisos:-
If hot water pipes pass at the rear, they should be lagged
and a 50 mm air gap provided to the left-hand side of the
appliance.
NOTE: It is advisable that the supply cable is routed away
from any hot surfaces i.e. hot water/ue pipes.
In the interest of safety, due consideration must be given to
the protection of the electric cable to the appliance.
If a supply cord is damaged it must be replaced by the
manufacturer, its service agent or similarly qualied
persons in order to avoid a hazard.
The AGA Module requires a 30 amp power supply and must
be connected to the mains with a cable which complies with
SAA Wiring Rules as 3000.
The appliance is designed for the voltage stated on the rating
plate, which is situated in the centre vent slot near the base of
the front plate.
Recommended, but not mandatory, to t an individual
Residual Current Device (RCD) for the appliance’s supply
circuit to avoid nuisance tripping.
A minimum clearance of 1000 mm must be available at the
front of the appliance to enable it to be serviced.
DO NOT install the appliance behind a decorative
door in order to avoid overheating.
Levelling
The AGA Module is designed to stand on a at surface,
however any unevenness may be overcome by packing under
the corners of the plinth with a suitable non-combustible
material, 3mm.