12. Installation Sequence & Procedure
Having ensured all space requirements and regulations have
been satised for the combined arrangement (AGA Total
/ Dual Control & Module), the build and installation is to
proceed as follows:-
It is essential that the base or hearth on which both
appliance(s) and module stands should be level and capable
of supporting the total weight of both units. Refer to the
technical data for the weight of each appliance(s).
1. Unpack and remove the Module from the pallet.
2. Check that the rear extension piece is secured to the left
hand side panel.
3. Release 2 screws from front tongue bracket and allow
the bracket to drop downwards. Now slide the Module
o its plinth and set to one side Fig. 12.1.
4. The Module plinth can now be levelled and tted up
to the main appliance. Position the Module plinth
alongside the AGA TC3/DC3 leaving no gap between
the two plinths. (See Fig. 12.2).
5. When tting the Module onto a AGA TC5/DC5 there
should be a gap of 4.5 mm (See Fig. 12.3).
6. PLEASE NOTE: When tting a Module plinth to an AGA
TC5 or AGA DC5 the 2 adjustment screws should be
screwed in from the outside (until they are fully in). The
screw heads will set a gap of 4.5 mm between plinths.
7. Check with a spirit level that the plinth is correct and
using a straight edge check that both plinths are aligned
along the front face (using either front or rear plinth
adjustment screw to alter alignment, if necessary).
8. Also check height dierential between the Module
plinth and AGA Total/Dual Control plinth is correct:
11 mm. If necessary, use the adjusting studs in each
corner to level the plinth. In extreme instances, shims
may be used underneath the plinths (See Fig. 12.2 or
Fig. 12.4).
9. Attach Module plinth to the AGA Total/Dual Control
plinth using 2x M6 screws and washers provided (See
Fig. 12.5 or Fig. 12.6). Slide front jointing bracket into
place over two adjacent magnets, locking the two
appliances together.