Agilent 5100 and 5110
ICP-OES
User’s Guide

Table of Contents

Other manuals for Agilent Technologies 5100 ICP-OES

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 5100 ICP-OES and is the answer not in the manual?

Agilent Technologies 5100 ICP-OES Specifications

General IconGeneral
Wavelength Range167 - 785 nm
Warm-up TimeApproximately 30 minutes
TypeInductively Coupled Plasma Optical Emission Spectrometer (ICP-OES)
Plasma GeneratorSolid-state RF generator
DetectorSegmented array Charge Coupled Device (CCD)
Sample Introduction SystemIncludes peristaltic pump, nebulizer, and spray chamber
Plasma ViewRadial and axial view configurations
TorchDemountable torch
Auxiliary Gas Flow Rate0.5-1.5 L/min
Nebulizer Gas Flow Rate0.5-1.0 L/min
Sample Uptake Rate1-2 mL/min
Memory EffectsMinimized through efficient spray chamber design and rinse cycles
Power Requirements200-240 VAC, 50/60 Hz, single phase

Summary

Safety Practices and Hazards

Electrical Hazards

Warns of dangerous voltages in circuits and components, and shock hazards from improper grounding.

Installation

Agilent ICP-OES Instrument Overview

Provides a labeled diagram of the front and side of the ICP-OES instrument.

Instrument Status LED Color Coding

Explains the meaning of different LED colors indicating instrument status and operational readiness.

Front Power OnOff Button

Describes the LED indicator on the front power button and its states.

ICP Expert Software

Details the installation of ICP Expert software by trained personnel or the user.

Connecting ICP Expert software to the ICP-OES

Provides step-by-step instructions to connect the ICP Expert software to the instrument.

Hardware Components Replacement

Refers to the Familiarization DVD or ICP Expert Help for setting up components like pump/torch.

Torch Assembly and Disassembly

Explains how to assemble and disassemble demountable torch models for cleaning.

Operation

Analysis Checklist

Lists sequential steps needed to measure a sample, including PC, instrument, and software setup.

Turning On the Instrument and Software

Provides step-by-step instructions for initial power-up and startup of the instrument and software.

Preparing for Analysis

Guides on preparing the instrument for analysis, including igniting plasma and setting up the pump.

Performing a Detector and Instrument Calibration

Details how to perform detector and wavelength calibration procedures.

CreatingOpening a Worksheet

Instructions on creating new worksheets or opening existing ones for analysis setup.

Developing a Method

Guides on configuring features, selecting elements, wavelengths, and analytical conditions.

Running Samples

Provides steps to set up the autosampler and run samples using the ICP Expert software.

Printing a Report

Explains how to generate, preview, and print analysis reports using the software.

Maintenance and Troubleshooting

Torch Cleaning

Guides on cleaning the torch, including acid cleaning for aqueous samples and carbon build-up.

Troubleshooting

Directs users to the ICP Expert Help for troubleshooting information and procedures.