Programming with a Series 200/300 Computer
105
10 ASSIGN @Ps TO 705
20 OUTPUT @Ps;’VSET?1’
30 ENTER @Ps;Vsl
40 OUTPUT @Ps;"ISET?1"
50 ENTER @Ps;Isl
60 PRINT ’VOLTAGE SETTING OF OUTPUT #1 = ";Vsl
70 PRINT "CURRENT LIMIT SETTING OF OUTPUT #1 = ";Isl
80 END
Line 10: Assigns the I/O pathname to the power supply.
Line 20,30: Queries the supply for output 1’s voltage setting. You cannot string multiple queries together in a single
device command because the power supply can only return the most recently queried data.
Line 40,50: Queries the supply for output 1’s current limit.
Line 60,70: Prints the results of the queries on the screen.
Programming Power Supply Registers
Present Status
The power supply makes available several forms of status information. Chapter 5 discusses the different registers and their
functions. The present status register contains continuously updated information. The following example shows how to
query bit position 0 of output 1’s status register to see if output 1 is in CV mode. In this example, the program references the
function as a variable in a conditional execution statement. Note that instead of printing a message, line 30 could be used to
branch to another part of the program in the event that the supply is in CV mode.
10 ASSIGN @Ps TO 705
20 COM /Ps/ @Ps
30 IF FNCv _ mode THEN
40 PRINT "OUTPUT 1 IS IN CV MODE"
50 END IF
60 END
70 !
80 !
90 DEF FNCv _ mode
100 COM /Ps/ @Ps
110 OUTPUT @Ps;STS?1"
120 ENTER @Ps;Sts
130 RETURN BIT(Sts,0)
140 FNEND
Line 10: Assigns the I/O path name to the power supply.
Line 20: Declares a common block for the I/O path name. The COM statement must be used for the @Ps variable
to preserve its value in the function subprogram.
Line 30,40,50: If FNCv _ mode is true, print the message.
Line 90: Defines the Cv _ mode function.
Line 100: Brings in the common block for the I/O pathname.
Line 110,120: Reads the present status of output 1 into the variable Sts.
Line 130: Returns the value of bit position 0 of Sts.

Table of Contents

Other manuals for Agilent Technologies 6625A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 6625A and is the answer not in the manual?

Agilent Technologies 6625A Specifications

General IconGeneral
BrandAgilent Technologies
Model6625A
CategoryPower Supply
LanguageEnglish

Related product manuals