Code Message Cause
-101 Invalid character Unrecognized character in specified parameter.
-102 Syntax error Command is missing a space or comma between parameters.
-103 Invalid separator Command parameter is separated by some character other
than a comma.
-104 Data type error The wrong data type (i.e. number, character, string
expression) w as used w hen specifying a parameter.
-108 Parameter not allowed Parameter specified in a command which does not require
one (e.g., SYSTem:ERRor? 10).
-109 Missing parameter No parameter specified in the command in which a
parameter is required.
-113 Undefined header Command header w as incorrectly specified (e.g., * IDN1?).
-123 Numeric overflow A parameter specifies a value greater than the command
allows.
-128 Numeric data not allow ed A number w as specified for a parameter w hen a letter is
required.
-131 Invalid suffix Parameter suffix incorrectly specified (e.g. .SSECOND rather
than .SS or .SSEC).
-138 Suffix not allow ed Parameter suffix is specified w hen one is not allow ed.
-141 Invalid character data The discrete parameter specified is not allowed (e.g.
TRIG:SOUR INT - INT is not a choice.).
-178 Expression data not allowed A parameter is enclosed in parentheses that should not be.
-211 Trigger Ignored Trigger occurred while the Pacer is in the idle state, or a
trigger occurred from a source other than the specified
source.
-222 Data out of range The parameter value specified is too large or too small.
-224 Illegal parameter value The numeric value specified is not allowed.
-240 Hardw are error Hardware error detected during pow er-on cycle. Return
mainframe to Agilent Technologies for repair.
-310 System error If caused by * DMC, then macro memory is full.
-350 Too many errors The error queue is full as more than 30 errors have occurred.
-410 Query interrupted Data is not read from the output buffer before another
command is executed.
-420 Query unterminated Controller tried to read data without first sending a complete
query message.
-430 Query deadlocked Command execution cannot continue since the mainframes
command input, and data output buffers are full. Clearing the
instrument restores control.
+ 1500 External trigger source Event In signal already allocated to another already
allocated instrument such as a Switchbox.
+ 2002 Invalid logical address A value less than 0 or greater than 255 was specified for a
logical address.
Table A-3. System Errors
In Case Of Difficulty A-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 75000 Series B and is the answer not in the manual?

Agilent Technologies 75000 Series B Specifications

General IconGeneral
BrandAgilent Technologies
Model75000 Series B
CategoryControl Unit
LanguageEnglish

Related product manuals