SCPI Commands Appendix B
Model N6705 User’s Guide 185
SCPI Command Description
FETCh[:SCALar] (continued)
:VOLTage
[:DC]? (@chanlist)
Returns the average voltage
:ACDC? (@chanlist)
Returns the total rms voltage (AC + DC)
:HIGH? (@chanlist)
Returns the high level of a voltage pulse
:LOW? (@chanlist)
Returns the low level of a voltage pulse
:MAXimum? (@chanlist)
Returns the maximum voltage
:MINimum? (@chanlist)
Returns the minimum voltage
:ARRay
:CURRent [:DC]? (@chanlist)
Returns the instantaneous output current
:POWer [:DC]? (@chanlist)
Returns the instantaneous output power
:VOLTage [:DC]? (@chanlist)
Returns the instantaneous output voltage
:DLOG
:AHOur? (@chanlist)
Returns the amp-hours between markers
:CURRent
[:DC]? (@chanlist)
Returns the average current between markers
:MAXimum? (@chanlist)
Returns the maximum current between markers
:MINimum? (@chanlist)
Returns the minimum current between markers
:PTPeak? (@chanlist)
Returns the peak-to-peak current between markers
:VOLTage
[:DC]? (@chanlist)
Returns the average voltage between markers
:MAXimum? (@chanlist)
Returns the maximum voltage between markers
:MINimum? (@chanlist)
Returns the minimum voltage between markers
:PTPeak? (@chanlist)
Returns the peak-to-peak voltage between markers
:WHOur? (@chanlist)
Returns the watt-hours between markers
:ELOG <NR1>, (@chanlist)
Returns the most recent external data log records
:HISTogram
:CURRent? 8 | 0.0039, (@chanlist)
Returns the cumulative histogram current data (N6781A, N6782A)
FORMat
[:DATA] ASCII | REAL
Returns data as ASCII or binary
:BORDer NORMal | SWAPped
Sets the byte order of the external data log data
HCOPy:SDUMp:DATA?
Returns an image of the display in .gif format
INITiate
[:IMMediate]
:ACQuire (@chanlist)
Enables measurement triggers
:DLOG <“filename”>
Enables the data logger function
:ELOG (@chanlist)
Enables external data logger measurements
:HISTogram (@chanlist)
Enables histogram measurements (only on N6781A, N6782A)
:TRANsient (@chanlist)
Enables output triggers
:CONTinuous
:TRANsient <Bool>, (@chanlist)
Enables/disables continuous transient triggers
MEASure
[:SCALar]
:CURRent
[:DC]? (@chanlist)
Takes a measurement; returns the average current
:ACDC? (@chanlist)
Takes a measurement; returns the total rms current (AC + DC)
:HIGH? (@chanlist)
Takes a measurement; returns the high level of a current pulse
:LOW? (@chanlist)
Takes a measurement; returns the low level of a current pulse
:MAXimum? (@chanlist)
Takes a measurement; returns the maximum current
:MINimum? (@chanlist)
Takes a measurement; returns the minimum current

Table of Contents