N9310A RF Signal generator
Quick Start Guide 13
Generating a Modulated Signal
To simplify the example, assume you wish to generate an
amplitude modulated (AM) signal with a:
• Carrier frequency of 900 MHz
• Carrier power level of –20.0 dBm
• AM depth of 60%
Setting up carrier frequency and amplitude
Setting up Amplitude Modulation
Operation Notes
1. Press hardkey.
Sets the signal generator to its
factory-defined instrument state.
2. Press >
900 > MHz
Sets the carrier frequency to 900 MHz for
amplitude modulation.
3. Press
>–20 > dBm
Sets the carrier amplitude to –20 dBm for
amplitude modulation.
Operation Notes
1. Press
hardkey.
Displays the
AM first level menu.
2. Press
AM Depth > 60 > % Set the AM depth to 60%.
3. Press
AM On Off softkey.
AM toggles from
Off to On. The
indicates “On” signifying that you have
enabled amplitude modulation.
Preset
Frequency
Amplitude
AM