en | AHT Cooling Systems GmbH Maintenance | 11
405859_1_0819 41 / 505
10.2.2 Restart
For restarting, see Start-up.
10.3 Malfunctions during operation
NOTICE
Material and property damage in the event of
an alarm display.
Move the goods to another appliance with the
same product temperature class.
Contact the maintenance service promptly
(see Maintenance services).
Display of alarms
There are different types of alarms that indicate mal-
functions during operation.
Display indicator (see page 11, chapter 5).
Error code
Flashing red dot
Acoustic alarm
11 Maintenance
Inspection tasks by operating personnel
Inspection tasks
Frequency
See Section
Proper condition of
appliances
Ongoing
Use as intended
Operation
Foreign objects in
goods area
Ongoing
Use as intended
Operation
Damage glass ele-
ment
Ongoing
Mechanical haz-
ards
Operation
Interior temperature
Several
times a day
Temperature dis-
play
Operation
Proper loading with
goods
Ongoing
Loading
Contamination of the
appliance, including
glass
Daily
Cleaning steps
Food and packaging
residues
Daily
Cleaning steps
Floor (surroundings
of the appliance)
Daily
Cleaning steps
Formation of ice on
the inner container
Ongoing
defrosting
Closed lids
Ongoing
Mechanical haz-
ards
Operation
Puddles in front
of/underneath appli-
ance (condensation
water)
Daily
Automatic de-
frosting
Mechanical haz-
ards
Condensation water
sieve
Ongoing
Page 20, chapter
11.2.1
WARNING
Electrostatic discharge and spark for-
mation with flammable refrigerant.
On a damaged / leaking refrigerant circuit,
sparks may ignite escaping refrigerant. Fire
hazard.
Use a damp cloth or sponge to re-
move condensation water.
Do not use dry cloths or sponges to
dry the appliance.
Do not operate any electrical devices
(e.g. wet vacuum cleaners) inside
the cooling compartment that do not
correspond to the design recom-
mended by the manufacturer. Appli-
ances with explosion protection
markings (see Explanation of
symbols) are permitted.
11.1 Defrosting
Responsibility
Operating companies
Operating personnel
The appliance features automatic defrosting.
If there is an increased formation of ice in the inner
container, a semi-automatic defrosting must be
started (see page 11, chapter 5).
For hygienic reasons, complete defrosting must be
carried out (see page 19, chapter 11.1.1).
11.1.1 Complete defrosting
We recommend combining the complete defrosting
with the basic cleaning.
Defrosting interval
For hygienic reasons, at least every six
months
Carrying out a complete defrosting
Carrying out a complete defrosting is equivalent to the
cleaning steps with the cooling function switched off.
(see page 20, chapter 11.2.1).
11.2 Cleaning
Reasons for regular and thorough cleaning (basic
cleaning):
Ensuring the necessary hygiene. Always keep
the goods area in a clean condition.
Lowest possible energy consumption.
Maintaining trouble-free operation.
Extension of the service life of the appliance.

Table of Contents

Other manuals for AHT PARIS 185

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AHT PARIS 185 and is the answer not in the manual?

AHT PARIS 185 Specifications

General IconGeneral
BrandAHT
ModelPARIS 185
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals