Operating Instruction & Parts Manual
SELF DIAGNOSTIC CODES
The alarm light is activated if abnormal operation occurs, and an error code is displayed on the control panel.
I
n this case, the compressor will stop operating.
Error Code Problem Cause Corrective Action
Water full
Align water tank
High pressure
Low pressure
Sensor Problem
Anti-Freezing
alarm
Fire alarm signal
Condensate tank is full Empty the water tank
Water tank is not posi-
tioned correctly
Place the water tank
in right position
Blocked air filter
Blocked / kinked exhaust duct
Ambient temperature is too high
Ensure exhaust duct is not
blocked / kinked
Do not use the air conditioner if
ambient temperature is higher
than 113
Temperature sensor has
an electric short.
Exchange temperature sensor
(Contact Airrex U.S.A. at 1-888-
535-8841)
Evaporator is below 25
(-4 ) due to being used in a
low ambient
temperature area.
Do not use the unit in an ambient
temperature less than 72 (22).
Check refrigerant level.
Fire alarm signal is received
from Fire alarm system.
Reset unit by pushing and
holding the "OFF TIMER" button
for 5 seconds.
Verify Electrical
Refrigerant may be low
Clean Filters and Coils
Verify Power (Voltage/Amps)
Check Filters Evaporator/Condenser
Check Evaporator/Condenser Coils
Check refrigerant level and/or
refrigerant leak.