TROUBLE CHECK REMEDY
Power plug correctly connected
Connect plug correctly
POWER button OFF”●Press POWER button to ON
Fuse (supply) blown Replace fuse
Breaker on switch board Check load capacity and reset
tripped
Ambient temp. too high Use only below 113℉,45
(over 113℉,45)
Filter blocked with dust Clean Filter
Dust in heat exchanger Clean heat exchanger
Obstacle against inlet side Remove and allow 20" (51 cm) clearance
Ambient temp. too high Use only below 113℉,45
(over 113℉,45)
1. To remove filters, slide up a little and pull
towards you .
2. Clean the filters with water or compressed air.
3. Clean evaporator and condenser units with a
vacuum cleaner or compressed air.
1. After cleaning, completely dry
the inside of the unit by
operating on Fan Mode
for 3 to 4 hours.
2. Turn OFFat control panel,
remove plug from socket. Coil
and store cable neatly.
3. Keep machine suitably covered to
prevent damage by damp,
humidity and dust.
MAINTENANCE
CLEANING THE AIR FILTERS
MAINTENANCE
rev0-2011
Operating Instruction & Parts Manual
NOT
WORKING
POOR
COOLING
TROUBLESHOOTING CHART