Do you have a question about the Airwell ELECTRA HDDE Series and is the answer not in the manual?
Brand | Airwell |
---|---|
Model | ELECTRA HDDE Series |
Category | Air Conditioner |
Language | English |
Overview of the HDDE series mono-split DCI inverter air conditioner and its high-wall mounted type indoor units.
Key technological innovations and benefits of the air conditioning unit, including DC inverter and high SEER/SCOP.
Details about the wall-mounted indoor unit, its features like LED display, variable speed motor, and filtration system.
Information on the microprocessor indoor controller and infrared remote control (RC 8A) for system operation.
Description of the outdoor units, installation methods, and protective features like anti-corrosion paintwork.
Details on flare type interconnecting tubing and supplied documentation, including installation and operation manuals.
A table illustrating compatible combinations between indoor and outdoor units for different models.
Technical data for indoor and outdoor units, including capacity, efficiency, power supply, and dimensions for model VDDE009.
Detailed technical specifications, performance ratings, and dimensions for the VDDE012 outdoor unit model.
Comprehensive technical data, performance characteristics, and physical dimensions for the VDDE018 outdoor unit model.
Technical data, performance ratings, and physical dimensions for the VDDE024 outdoor unit model.
Specifies the standard indoor and outdoor temperature and humidity conditions for cooling and heating operations.
Defines the acceptable minimum and maximum operating temperature limits for cooling and heating, and voltage range.
Provides detailed dimensional drawings and a table for JEDE009, JEDE012, JEDE018, and JEDE024 indoor units.
Dimensional drawings and specifications for the VDDE009 outdoor unit, showing width, height, and depth.
Dimensional drawings and specifications for the VDDE012 outdoor unit, detailing its physical measurements.
Visual representation and measurements for the VDDE018 outdoor unit, including overall dimensions.
Dimensional drawings and specifications for the VDDE024 outdoor unit, showing its physical layout and sizes.
Graphs illustrating the relationship between compressor speed and current consumption for cooling and heating modes for various models.
Tables showing standard pressure, pipe temperatures, and compressor revolution under different operating conditions for cooling and heating.
Diagrams illustrating the measurement methods for sound pressure level in different installation scenarios (wall, floor, ducted, cassette).
Graphs showing indoor noise levels based on fan motor speed and compressor frequency for cooling and heating modes.
Table detailing power supply, maximum current, circuit breaker rating, and wiring specifications for outdoor units VDDE009 to VDDE024.
Schematic diagram illustrating the internal wiring connections for the JEDE009 and JEDE012 indoor units.
Wiring schematic for the JEDE018 indoor unit, showing connections between components.
Wiring diagram for the JEDE024 indoor unit, detailing internal electrical connections.
Schematic showing the wiring connections for the VDDE009 outdoor unit, including main components.
Wiring diagram for the VDDE012 outdoor unit, illustrating the electrical connections and layout.
Wiring schematics for the VDDE018 and VDDE024 outdoor units, detailing component connections.
Diagrams showing the refrigerant flow path for JEDE009/VDDE009 and JEDE012/VDDE012 unit combinations.
Diagrams illustrating the refrigerant circulation for JEDE018/VDDE018 and JEDE024/VDDE024 unit combinations.
Detailed guide on connecting refrigerant pipes, including tube bending, torque specifications, and necessary tools.
Explanation of the electronic control system, including abbreviations and the system operation concept between indoor and outdoor units.
Details on how compressor frequency is managed using PI control, including frequency range and change rates.
Information on compressor starting procedures, minimum on/off times, and indoor fan speed control modes.
Explanation of operational modes like Fan, Cool, Heat, and refrigerant control methods (EEV, Capillary).
Logic for cooling operations based on room temperature (RAT) and set point temperature (SPT) for different models.
Logic for heating operations based on room temperature (RAT) and set point temperature (SPT) for different models.
Logic for automatic selection of cooling, heating, or fan mode based on room temperature.
Operation details for Dry mode and how the louver (air deflector) controls swing and position.
Features for sleep mode, I-Feel function for maintaining room temperature, and the clean function.
Overview of protection codes and detailed descriptions for Indoor Coil Defrost and Compressor Overheating Protection.
Details on Outdoor Coil Overheating, Compressor Over Current, and Outdoor Coil Deicing Protections.
Information on Compressor Overload, AC Over Current, Deicing Procedures, and Exiting Deicing conditions.
Protections related to AC Voltage Drop, Communication Malfunction, and Compressor Overload.
Details on IPM module protection, modular overheating, and sensor failure error codes.
How to operate the unit using the ON/OFF button, indoor unit indicators, and test mode procedures.
Precautions and initial confirmation steps before troubleshooting electrical and control issues in the unit.
Guide for interpreting error codes displayed by indoor and outdoor units based on malfunction and LED indicators.
A comprehensive table detailing various malfunctions, error codes, possible causes, and recommended actions for troubleshooting.
Procedures for checking the refrigeration system, mains voltage, power input, fan motor, compressor, and reverse valve.
Resistance-temperature chart for the Room Air Temperature (RAT) and Outdoor Air Temperature (OAT) sensors.
Resistance-temperature chart for the Indoor Coil Temperature (ICT) and Outdoor Coil Temperature (OCT) sensors.
Resistance-temperature chart for the Compressor Top Temperature (CTT) sensor.
Exploded diagram showing the assembly of JEDE009 and JEDE012 indoor units with numbered parts.
Detailed list of spare parts for the JEDE009 indoor unit, including part codes and quantities.
Spare parts list for the JEDE012 indoor unit, specifying part codes, descriptions, and quantities.
Exploded view diagram illustrating the assembly of the JEDE018 indoor unit with corresponding part numbers.
Comprehensive spare parts list for the JEDE018 indoor unit, including part codes and descriptions.
Exploded diagram showing the assembly of the JEDE024 indoor unit, with numbered components for identification.
List of spare parts for the JEDE024 indoor unit, detailing part codes, descriptions, and quantities.
Exploded diagram of the VDDE009 and VDDE012 outdoor units, showing component layout.
Spare parts list for the VDDE009 outdoor unit, including part codes, descriptions, and quantities.
List of spare parts for the VDDE012 outdoor unit, with part codes, descriptions, and quantities.
Exploded diagram illustrating the assembly of the VDDE018 outdoor unit with numbered components.
Spare parts list for the VDDE018 outdoor unit, detailing part codes, descriptions, and quantities.
Exploded diagram showing the assembly of the VDDE024 outdoor unit with numbered parts.
List of spare parts for the VDDE024 outdoor unit, including part codes, descriptions, and quantities.
Guidelines for analyzing and processing malfunctions in indoor units, including compressor protection and sensor issues.
Recommendations for servicing outdoor units and contacting service centers for solutions and documentation.