REV: 0 FEB 2009

Questions and Answers

  • M
    Ms. Lisa FosterAug 15, 2025
    What to do if my Airwell EDS25 Air Conditioner is not cooling or heating, but the indoor fans are working?
    • M
      Matthew WilliamsAug 15, 2025
      If your Airwell Air Conditioner's overload safety device on the compressor has cut out due to low voltage or high temperature, check for proper voltage and try again after one hour. If the compressor run capacitor is faulty, replace it. If the compressor windings are shorted, replace the compressor.
  • W
    wesley30Aug 18, 2025
    What to do if my Airwell EDS25 Air Conditioner has no cooling or heating, and only the indoor fan works?
    • M
      michael22Aug 19, 2025
      If your Airwell Air Conditioner has no cooling or heating and only the indoor fan works, the outdoor fan motor may be faulty, or another fault has occurred causing the compressor overload protection to cut out. Replace the P.C.B. Also check if the outdoor fan is blocked and remove any obstructions.
  • M
    mweaverAug 22, 2025
    How to fix water accumulation from the indoor unit section of my Airwell EDS25 Air Conditioner?
    • C
      Cody SanchezAug 22, 2025
      If water accumulates from the indoor unit section of your Airwell Air Conditioner, it is likely that the drain tube or spout of the drain pan is clogged. Disassemble the plastic drain tube from the spout of the indoor unit drain pan to resolve this issue.
  • A
    Amanda RichardsonAug 26, 2025
    Why is my Airwell Air Conditioner in heat mode but operating in cooling?
    • M
      Michael RobertsAug 26, 2025
      If your Airwell Air Conditioner is in heat mode but operating in cooling, it could be due to a faulty RV coil. Replace the RV coil. Alternatively, the RV coil might be okay, but the valve is stuck in a certain position, in that case replace the reversing valve.
  • M
    Melissa MejiaAug 28, 2025
    What to do if my Airwell EDS25 has only indoor fan and compressor working?
    • C
      Chris HarrisonAug 28, 2025
      If only the indoor fan and compressor are working on your Airwell Air Conditioner, the outdoor fan may be blocked. Remove any obstructions to resolve this.
  • W
    watsonemilySep 1, 2025
    What to do if my Airwell EDS25 Air Conditioner has no air supply at the indoor unit, but the compressor operates?
    • D
      Denise ThompsonSep 1, 2025
      If there is no air supply at the indoor unit of your Airwell Air Conditioner, but the compressor operates, the indoor fan motor may be blocked or turning slowly. Check the voltage and repair the wiring if necessary. Also, check if the fan wheel is tight enough on the motor shaft and tighten it if necessary.
  • C
    Christine BellSep 4, 2025
    Why is my Airwell Air Conditioner freezing up the outdoor coil in heating mode?
    • G
      Gregory ThompsonSep 4, 2025
      If your Airwell Air Conditioner's outdoor coil is freezing up in heating mode, resulting in a poor heating effect, it could be due to several reasons: a faulty outdoor thermistor (replace it), a faulty control cable (repair it), outdoor temperature being below design conditions (shut the unit off as it cannot work properly), or a blocked outdoor unit air outlet (remove obstructions).
  • D
    Dalton GonzalezSep 7, 2025
    Why is my Airwell EDS25 dripping water from the outdoor unit base in heating mode?
    • J
      Joshua SantosSep 7, 2025
      If water is dripping from the outdoor unit base of your Airwell Air Conditioner in heating mode, the water drain outlet is likely clogged. Open the outdoor unit cover, clean out the water outlet, and thoroughly clean the base inside.
  • D
    Dalton CaseSep 12, 2025
    Why does my Airwell Air Conditioner have a partial, limited air supply at the indoor unit?
    • B
      bellchaseSep 12, 2025
      A partial or limited air supply at the indoor unit of your Airwell Air Conditioner, accompanied by a whistling noise and ice formation on the indoor unit coil in cooling mode, indicates a lack of refrigerant. Charge the unit after localizing the leak.

Airwell EDS25 Specifications

General IconGeneral
Heating Capacity2.8 kW
Power Supply220-240V, 50Hz
RefrigerantR410A
TypeSplit System
Noise Level (Outdoor Unit)50 dB