12
The unit will continue to operate at the set temperature.
When set to 19˚C≥st≥25˚C:
During the 2 hours after Sleep mode 1 start up, the set temperature will decrease by
1˚C every hour. The unit will continue operating at 2˚C below the set temperature. 8
hours later, the set temperature will increase 2˚C; the unit will continue operating at
this temperature.
When set to 26˚C≥st≥31˚C:
During the 3 hours after Sleep mode 1 start up, the set temperature will decrease by
1˚C every hour. The unit will continue operating at 3˚C below the set temperature.
8 hours later, the set temperature will increase 2˚C; the unit will then continue
operating at this temperature.
Sleep Mode 2:
2
Whilst the air conditioner is in Cool and Dry mode
When set to 23˚C≥st≥16˚C:
During the 3 hours after Sleep mode 2 start up, the set temperature will increase by
1˚C every hour. The unit will continue operating at 3˚C above the set temperature.
7 hours later, the set temperature will decrease 1˚C; the unit will then continue
operating at this temperature.
When set to 24˚C≥st≥27˚C:
During the 2 hours after Sleep mode 2 start up, the set temperature will increase by
1˚C every hour. The unit will continue operating at 2˚C above the set temperature. 7
hours later, the set temperature will decrease 1˚C; the unit will continue operating
at this temperature.
When set to 28˚C≥st≥31˚C:
The unit will continue to operate at the set temperature.
Whilst the air conditioner is in Heat mode
When set to 18˚C≥st≥16˚C:
The unit will continue to operate at the set temperature.
When 19˚C≥st≥25˚C:
During the 2 hours after Sleep mode 2 start up, the set temperature will decrease by
1˚C every hour. The unit will continue operating at 2˚C below the set temperature. 7
hours later, the set temperature will increase 1˚C; the unit will continue operating at
this temperature.