Status Messages – Poll / Response
Message type 0x02 – Fault Status Poll
Header (29 bits) 2 22 11 00 0
8.....43......65......87......0
1100011101111 [ A ] [ B ]
3 bits, Priority 6 (110)
2 bits, 00
8 bits, 0xEF
[A] = 8 bits, Target (AB node address)
[B] = 8 bits, Source (Integrator node address)
Data length – 1 byte
Data byte 0
bit 7......0
00000010
8 bits, Message type 0x02
Example 18EF8005 [1] 02
This message requests fault status from the AB unit at CAN node address ‘0x80’ to be sent to the Integrator unit at CAN node
address ‘0x05’.
Message type 0x03 – Firmware Version Poll
Header (29 bits) 2 22 11 00 0
8..... 43...... 65......87...... 0
1100011101111 [ A ] [ B ]
3 bits, Priority 6 (110)
2 bits, 00
8 bits, 0xEF
[A] = 8 bits, Target (AB node address)
[B] = 8 bits, Source (Integrator node address)
Data length – 1 byte
Data byte 0
bit 7......0
00000011
8 bits, Message type 0x03
Example – 18EF8005 [1] 03
This message requests firmware version information from the AB unit at CAN node address ‘0x80’ to be sent to the Integrator unit at
CAN node address ‘0x05’.