FUNCTIONS
Functions
From Standby, the controller can enter 1 of 3 manually selected modes (Auxiliary/Test/Settings) or an
automatic Running mode triggered by a flow signal input..
From Standby ..
To enter Auxiliary Mode: Press F button momentarily.
To enter Test Mode: Press and hold F button >3 seconds
To enter Settings Mode: Press UP and DOWN buttons simultaneously >3 seconds
Auxiliary Mode
Pump starts immediately (no start delay).
Press F button momentarily: Pump stops immediately (no run-on time) and controller returns to
Standby Mode.
Note: If no button is pressed within 30 minutes, pump stops immediately and controller returns to
Standby Mode.
Note: Auxiliary Mode is also triggered by switch closure (momentary or latching) at Auxiliary
switch terminals.
Test Mode
Controller initiates Countdown delay.
Pump starts and runs at maximum capacity for 10 seconds.
Controller initiates Run-On timer.
Pump stops and controller returns to Standby Mode.
Note: Press F momentarily during test sequence to exit mode. Controller returns to Standby Mode.
Settings Mode
Press F button momentarily: Cycle through parameter index.
Press Up or Down button momentarily: Increment or decrement parameter value.
Press F button >3 seconds: Settings saved and controller returns to Standby Mode.
Note: If no button is pressed within 10 seconds, controller returns to Standby Mode and settings
changes are not saved.
Running Mode
When external triggered applied ..
Controller initiates Countdown delay.
Pump starts and runs at capacity determined by parameter settings.
When external trigger removed ..
Controller initiates Run-On timer.
Pump stops and controller returns to Standby Mode.
Note: Pump rate can be calibrated by pressing UP and DOWN buttons simultaneously for >3 seconds
while in Running Mode.
Calibration Mode ..
Press UP or DOWN button momentarily: Increase or decrease pump rate.
Press F button >3 seconds: calibration value saved and controller returns to Running Mode.
Press UP and DOWN buttons simultaneously for >3 seconds: calibration value not saved and
controller returns to Running Mode.