automatically. If unsuccessful, the address must be enabled manually via programming *196.
If another keypad is occupying this address already, a different address must be selected for the SEM. To select a
different keypad address, manually adjust the dual in-line package DIP switches on the SEM to match the desired
keypad address listed below. Then, exit programming via *99.
For additional information about enabling the keypad address, see What keypad address should be used with the SEM-
Honeywell/ADEMCO Vista?.
Keypad address DIP switch setting VISTA programming command
17 None—all OFF *190
18 Switch 4 ON, others OFF *191
19 Switch 3 ON, others OFF *192
20 Switch 3 and 4 ON, others OFF *193
21 Switch 2 ON, others OFF *194
22 Switch 2 and 4 ON, others OFF *195
23 Switch 2 and 3 ON, others OFF *196
Disarm and power down the panel
1. Verify the panel is disarmed and clear of any alarms, troubles, or system faults.
2. If you do not know the current installer code, check the installer code at the panel before powering down the panel.
3. Then remove AC power and disconnect the backup battery to completely power down the system.
Create an Alarm.com account
1. Create a new Alarm.com customer account using Partner Portal or MobileTech. The IMEI located on the
Alarm.com module will be needed to create this account.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/SEM_Honeywell_ADEMCO_Vista/SEM-Ho…