Page 298 7450 ESS OS Basic System Configuration Guide
Edit Mode
To enter the mode to edit timing references, you must enter the begin keyword at the
config>system>sync-if-timing# prompt.
Use the following CLI syntax to enter the edit mode:
CLI Syntax: config>system>sync-if-timing
begin
The following error message displays when the you try to modify sync-if-timing parameters
without entering the keyword begin.
A:ALA-12>config>system>sync-if-timing>ref1# source-port 2/1/1
MINOR: CLI The sync-if-timing must be in edit mode by calling begin before any changes can
be made.
MINOR: CLI Unable to set source port for ref1 to 2/1/1
A:ALA-12>config>system>sync-if-timing>ref1#