System Management
7450 ESS OS Basic System Configuration Guide Page 339
remote SNMP managers to be saved and reloaded in a CLI configuration file. The owner will not
normally be configured by CLI users and can be a maximum of 80 characters long.
Default TiMOS CLI
Configuration example:
Default event 5 rmon-event-type both description "alarm testing" owner "TiMOS CLI"
memory-use-alarm
Syntax memory-use-alarm rising-threshold threshold [falling-threshold threshold] interval seconds
[rmon-event-type] [startup-alarm alarm-type]
no memory-use-alarm
Context config>system>thresholds
Description The memory thresholds are based on monitoring the TIMETRA-SYSTEM-MIB sgiMemoryUsed object.
This object contains the amount of memory currently used by the system. The severity level is Alarm.
The
absolute sample type method is used.
The no form of this command removes the configured memory threshold warning.
Parameters rising-threshold thresholdSpecifies a threshold for the sampled statistic. When the current sampled
value is greater than or equal to this threshold, and the value at the last sampling interval was less than
this threshold, a single threshold crossing event will be generated. A single threshold crossing event
will also be generated if the first sample taken is greater than or equal to this threshold and the
associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated until the
sampled value falls below this threshold and reaches less than or equal the falling-threshold value.
Default 0
Values -2147483648 — 2147483647
falling-threshold thresholdSpecifies a threshold for the sampled statistic. When the current sampled
value is less than or equal to this threshold, and the value at the last sampling interval was greater than
this threshold, a single threshold crossing event will be generated. A single threshold crossing event
will also be generated if the first sample taken is less than or equal to this threshold and the associated
startup-alarm is equal to falling or either.
After a falling threshold crossing event is generated, another such event will not be generated until the
sampled value rises above this threshold and reaches greater than or equal the rising-threshold value.
Default 0
Values -2147483648 — 2147483647
interval secondsSpecifies the polling period over which the data is sampled and compared with the
rising and falling thresholds.
Values 1 — 2147483647
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.