Page 112 7450 ESS OS Basic System Configuration Guide
Parameters mac-filter-id — The MAC filter policy ID.
Values 1 65535
entry entry-id — Displays information on the specified filter entry ID for the specified filter ID only.
Values 1 — 65535
interval secondsConfigures the interval for each display in seconds.
Default 5 seconds
Values 3 — 60
repeat repeat Configures how many times the command is repeated.
Default 10
Values 1 — 999
absolute — When the absolute keyword is specified, the raw statistics are displayed, without processing.
No calculations are performed on the delta or rate statistics.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead of the
delta.
Sample Output
A:ALA-1>monitor>filter# mac 50 entry 10 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for Mac filter 50 entry 10
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
------------------------------------------------------------------------------
At time t = 3 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 6 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 9 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
===============================================================================
A:ALA-1>monitor>filter# mac 50 entry 10 interval 3 repeat 3 rate
===============================================================================
Monitor statistics for Mac filter 50 entry 10
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0
-------------------------------------------------------------------------------
At time t = 3 sec (Mode: Rate)
-------------------------------------------------------------------------------
Ing. Matches: 0 Egr. Matches : 0